ActivePure® Induct Guardian Dual (Model B1025A)
The Induct Guardian Dual attaches directly to the HVAC ductwork in the home and utilizes ActivePure Technology to reduce bacteria, viruses, and other contaminants in the air and on surfaces. The Induct Guardian Dual is best used in homes and indoor spaces of up to 2,500 square feet.
Benefits
The Induct Guardian Dual provides around-the-clock proactive air purification and surface decontamination for your home, while the HVAC system is running.
- Uses ActivePure Technology, proven to reduce up to 99.9% of many common types of bacteria, viruses, and mold in indoor air and surfaces1
- Reduces VOC gases, smoke, and odors without the use of ozone1
- Discreet or concealed installation
- Protects your heating and cooling system from potential buildup
- Solutions can be customized based on HVAC system, airflows, humidity, and other factors and is easily installed by a local HVAC technician
- Model B1025A meets California ozone emissions limit. CARB Certified
Validated to UL 2998
Specifications
Technology Included
ActivePure® Technology: 9” HO cells (Qty 2)
Environmental Certifications
Model B1025A meets California ozone emissions limit. CARB Certified
Validated to UL 2998
Electrical
Input Voltage: 120/277 VAC, 50/60 Hz
Current: 0.75 Amps | Power: 90 Watts
Mechanical
Distribution via air handler. Safety Switch Installed
Safety
Model B1025A conforms to UL 1995
Weight & Dimensions
6 lbs (2.72 kg)
8.5” H x 9.75” W x 11.5” D (21.59 cm x 24.765 cm x 29.21 cm)
Operating Temperature
34°F – 200°F (1.6°C – 93°C)
Recommended Maximum Coverage in a Contiguous Space*
Up to 2,500 sq. ft. (232m2) depending on occupant density and other factors
High density commercial not to exceed 1,250
For coverage in medical or healthcare environments, contact medical@activepure.com
Warranty
Limited 5 year warranty
Technology Included
- ActivePure® Technology: 9” HO cells (Qty 2)
Environmental Certifications
- Model B1025A meets California ozone emissions limit. CARB Certified
Validated to UL 2998
Electrical
- Input Voltage: 120/277 VAC, 50/60 Hz
- Current: 0.75 Amps | Power: 90 Watts
Mechanical
- Distribution via air handler. Safety Switch Installed
Safety
- Model B1025A conforms to UL 1995
Weight & Dimensions
- 6 lbs (2.72 kg)
- 8.5” H x 9.75” W x 11.5” D (21.59 cm x 24.765 cm x 29.21 cm)
Operating Temperature
- 34°F – 200°F (1.6°C – 93°C)
Recommended Maximum Coverage in a Contiguous Space*
- Up to 2,500 sq. ft. (232m2) depending on occupant density and other factors
- High density commercial not to exceed 1,250
- For coverage in medical or healthcare environments, contact medical@activepure.com
Warranty
- Limited 5 year warranty
*
Recommended ceiling height to not exceed 10 feet. Solutions should be customized based upon a variety of factors including HVAC system capabilities, HVAC settings, air flows (taking into account walls, air pressure, and doors), ambient air temperature, humidity, variable density, known VOC concentrations, and other layers of protection.